HEEALARX INDUSTRY LIMITED has developed a Monobloc Type Full Inverter EVI Air to Water House Heating Heat Pump for heating cooling specifically designed to meet the needs of the European market. This includes countries such as Poland, Czech Republic, Slovakia, Germany, Norway, Spain, France, and more.
This advanced monoblock inverter heat pump for heating cooling incorporates a range of modern elements, making it an excellent choice for both residential and commercial applications. Its key features include a high-performance Alfa Laval plate heat exchanger, the use of eco-friendly R32 refrigerant, full DC inverter technology, low noise operation, and a sleek modern appearance.
By integrating EVI technology, this monoblock type heat pump for heating and cooling delivers exceptional heating performance even in extremely low ambient temperatures. It provides a reliable and efficient solution for house heating, ensuring optimum comfort and energy savings.
Whether you are looking to upgrade your current heating system or seeking a sustainable solution for new construction projects, our Monobloc Type Full Inverter EVI Air to Water House Heating Heat Pump for heating and cooling is the perfect choice. It combines cutting-edge technology with a stylish design to enhance any space.
Please let me know if there’s anything else I can assist you with!
Availability: | |
---|---|
Quantity: | |
Brief Introduction
HEEALARX INDUSTRY LIMITED offers the HEEALARX series of full inverter heat pumps designed specifically for heating and cooling swimming pools. These monoblock inverter heat pumps have been meticulously engineered to provide exceptional features, such as super low noise levels, high heating efficiency, and the use of eco-friendly R32 refrigerant.
Our full inverter heat pumps for heating and cooling boast a modern patented design that adds an elegant touch to any pool area. The digital touch control panel, equipped with WIFI connectivity, allows for easy operation and remote access, providing convenient control and monitoring of the monoblock inverter heat pump for heating cooling system.
By utilizing HEEALARX’s full inverter heat pump for heating and cooling, you can enjoy a quiet and energy-efficient solution for heating your swimming pool while also reducing your environmental impact.
Why Choose HEEALARX Monobloc Inverter Air Source House Heating Heat Pump?
High-efficient A+++ Energy Level
Our monoblock-type full inverter heat pump for heating cooling system for house heating and cooling has been specifically tailored to meet the demands of the discerning European market. It offers an impressive A+++ energy label rating, attributed to its utilization of full inverter EVI technology and top-quality components.
By integrating a cutting-edge product structure with best-in-class components, our monoblock inverter heat pump for heating cooling system guarantees optimal energy efficiency and cost savings for customers. With its A+++ energy rating, it currently stands as the most energy-efficient and cost-effective choice in the market.
Mature full inverter technology
HEEALARX’s monoblock inverter heat pump for heating cooling system for house heating and cooling is the culmination of 8 years of research, design, and innovation by our international engineering team from Singapore and China. Throughout this period, we have acquired a deep understanding of the intricacies of full inverter technology and successfully integrated it into our product.
Cutting-edge Noise Reduction Technology
To ensure minimal noise levels, our monoblock inverter heat pump system incorporates various features. The utilization of the Panasonic full inverter EVI compressor and the DC inverter fan motor with adjustable fan speed contribute to a quieter operation. Furthermore, the system’s well-insulated piping and refrigerant system further enhance noise reduction.
By implementing these design considerations, the noise level of our monoblock inverter heat pump for heating cooling system can be effectively reduced to a range of 40-45 dB. This guarantees a quieter and more comfortable environment for users, whether in hospitals, residential buildings, or other applications.
Super Low Noise Level Technology
HEEALARX INDUSTRY LIMITED has implemented various features in their heat pump system to minimize noise levels. This includes the integration of the Panasonic full inverter EVI compressor and a DC inverter fan motor with adjustable fan speed, which allows for quieter operation. Additionally, the system incorporates well-insulated piping and a refrigerant system that further enhances noise reduction.
As a result of these thoughtful design considerations, the efficient monoblock inverter heat pump for heating cooling system from HEEALARX INDUSTRY LIMITED can effectively reduce noise levels to a range of 40-45 dB. This ensures a peaceful and comfortable environment for users, whether it’s in hospitals, residential buildings, or other applications.
R32 Gas
R32 gas, a newly introduced environmentally friendly and sustainable alternative to R410A, provides notable benefits. This green gas presents significant advantages, such as a 10%-20% increase in efficiency compared to R410A and reduced carbon consumption.Smart Digital Touch Control
The HEEALARX full inverter EVI air to water monobloc type heat pump for house heating comes equipped with a cutting-edge controller featuring a smart digital touch screen. This state-of-the-art touch screen interface adds a touch of sophistication to the product while providing users with a convenient and intuitive control experience.
One of the standout features of this heat pump for heating and cooling is its multi-language function, allowing users from different countries to select their preferred language. This ensures that the product is accessible and user-friendly for a diverse global customer base.
With its high-end controller and digital touch screen, the HEEALARX full inverter EVI air to water monobloc type heat pump offers not only exceptional heating performance but also a modern and user-friendly control interface.
Smart Digital Touch Control
The HEEALARX full inverter EVI air to water monobloc type heat pump for heating cooling is equipped with an advanced smart digital touch screen controller. This cutting-edge touch screen interface enhances the sophistication of the product and provides users with a convenient and user-friendly control experience.
One notable feature of this efficient monoblock inverter heat pump for heating and cooling is its multi-language function, allowing users from different countries to select their preferred language. This ensures that the product is accessible and user-friendly for a diverse global customer base.
With its high-end controller and digital touch screen, the HEEALARX full inverter EVI air to water monobloc type heat pump for heating and cooling not only delivers exceptional heating performance but also offers a contemporary and user-friendly control interface.
Anti-freezing protection
Monoblock inverter heat pumps, which comprise an indoor unit that circulates air over evaporator coils and an outdoor unit that powers the system, offer a multitude of benefits for homeowners. Among these advantages, a noteworthy feature of the monoblock design is its effective prevention of freezing problems. The system includes automatic anti-freezing protection by constantly monitoring the water temperature within the system. This functionality guarantees the smooth and efficient operation of the system, even in exceptionally frigid weather conditions.
EVI Technology
The full inverter EVI technology incorporated in our heat pump for heating and cooling unit allows for optimal performance even in extremely cold ambient temperatures as low as -25 degrees Celsius, and even -35 degrees Celsius. This advanced technology ensures that the unit provides stable and comfortable house heating as well as a reliable supply of hot water for end users. With the utilization of full inverter EVI technology, our monoblock inverter heat pump for heating and cooling system guarantees efficient and dependable operation in all weather conditions.
With Intelligent Defrosting
HEEALARX’s series of inverter heat pumps for heating and cooling feature advanced intelligent defrosting technology. This innovative technology allows the unit to make intelligent decisions based on the need for defrosting, resulting in minimized energy consumption and improved customer satisfaction.
Best quality heat pump components
In order to ensure the dependable performance of our units, HEEALARX INDUSTRY LIMITED employs premium heat pumpfor heating cooling components, which encompass the ALFA LAVAL Plate heat exchanger, WILO Inverter water pump (made in the EU), Panasonic R32 full inverter compressor, and Panasonic inverter fan motor. These top-notch components, known for their exceptional performance, are meticulously chosen to guarantee optimal efficiency and longevity for our monoblocl inverter heat pump systems.
Installation
HEELARX monoblock full inverter air water heat pumps for heating cooling can provide heating, cooling and domestic hot water. Floor heating loops is used for space heating while fancoil unit can be used for space heating and cooling.
Domestic hot water is supplied from the domestic hot water tank connected to the heat pump.
Traditional Installation
Installation with Multi Functional Tank
Brief Introduction
HEEALARX INDUSTRY LIMITED offers the HEEALARX series of full inverter heat pumps designed specifically for heating and cooling swimming pools. These monoblock inverter heat pumps have been meticulously engineered to provide exceptional features, such as super low noise levels, high heating efficiency, and the use of eco-friendly R32 refrigerant.
Our full inverter heat pumps for heating and cooling boast a modern patented design that adds an elegant touch to any pool area. The digital touch control panel, equipped with WIFI connectivity, allows for easy operation and remote access, providing convenient control and monitoring of the monoblock inverter heat pump for heating cooling system.
By utilizing HEEALARX’s full inverter heat pump for heating and cooling, you can enjoy a quiet and energy-efficient solution for heating your swimming pool while also reducing your environmental impact.
Why Choose HEEALARX Monobloc Inverter Air Source House Heating Heat Pump?
High-efficient A+++ Energy Level
Our monoblock-type full inverter heat pump for heating cooling system for house heating and cooling has been specifically tailored to meet the demands of the discerning European market. It offers an impressive A+++ energy label rating, attributed to its utilization of full inverter EVI technology and top-quality components.
By integrating a cutting-edge product structure with best-in-class components, our monoblock inverter heat pump for heating cooling system guarantees optimal energy efficiency and cost savings for customers. With its A+++ energy rating, it currently stands as the most energy-efficient and cost-effective choice in the market.
Mature full inverter technology
HEEALARX’s monoblock inverter heat pump for heating cooling system for house heating and cooling is the culmination of 8 years of research, design, and innovation by our international engineering team from Singapore and China. Throughout this period, we have acquired a deep understanding of the intricacies of full inverter technology and successfully integrated it into our product.
Cutting-edge Noise Reduction Technology
To ensure minimal noise levels, our monoblock inverter heat pump system incorporates various features. The utilization of the Panasonic full inverter EVI compressor and the DC inverter fan motor with adjustable fan speed contribute to a quieter operation. Furthermore, the system’s well-insulated piping and refrigerant system further enhance noise reduction.
By implementing these design considerations, the noise level of our monoblock inverter heat pump for heating cooling system can be effectively reduced to a range of 40-45 dB. This guarantees a quieter and more comfortable environment for users, whether in hospitals, residential buildings, or other applications.
Super Low Noise Level Technology
HEEALARX INDUSTRY LIMITED has implemented various features in their heat pump system to minimize noise levels. This includes the integration of the Panasonic full inverter EVI compressor and a DC inverter fan motor with adjustable fan speed, which allows for quieter operation. Additionally, the system incorporates well-insulated piping and a refrigerant system that further enhances noise reduction.
As a result of these thoughtful design considerations, the efficient monoblock inverter heat pump for heating cooling system from HEEALARX INDUSTRY LIMITED can effectively reduce noise levels to a range of 40-45 dB. This ensures a peaceful and comfortable environment for users, whether it’s in hospitals, residential buildings, or other applications.
R32 Gas
R32 gas, a newly introduced environmentally friendly and sustainable alternative to R410A, provides notable benefits. This green gas presents significant advantages, such as a 10%-20% increase in efficiency compared to R410A and reduced carbon consumption.Smart Digital Touch Control
The HEEALARX full inverter EVI air to water monobloc type heat pump for house heating comes equipped with a cutting-edge controller featuring a smart digital touch screen. This state-of-the-art touch screen interface adds a touch of sophistication to the product while providing users with a convenient and intuitive control experience.
One of the standout features of this heat pump for heating and cooling is its multi-language function, allowing users from different countries to select their preferred language. This ensures that the product is accessible and user-friendly for a diverse global customer base.
With its high-end controller and digital touch screen, the HEEALARX full inverter EVI air to water monobloc type heat pump offers not only exceptional heating performance but also a modern and user-friendly control interface.
Smart Digital Touch Control
The HEEALARX full inverter EVI air to water monobloc type heat pump for heating cooling is equipped with an advanced smart digital touch screen controller. This cutting-edge touch screen interface enhances the sophistication of the product and provides users with a convenient and user-friendly control experience.
One notable feature of this efficient monoblock inverter heat pump for heating and cooling is its multi-language function, allowing users from different countries to select their preferred language. This ensures that the product is accessible and user-friendly for a diverse global customer base.
With its high-end controller and digital touch screen, the HEEALARX full inverter EVI air to water monobloc type heat pump for heating and cooling not only delivers exceptional heating performance but also offers a contemporary and user-friendly control interface.
Anti-freezing protection
Monoblock inverter heat pumps, which comprise an indoor unit that circulates air over evaporator coils and an outdoor unit that powers the system, offer a multitude of benefits for homeowners. Among these advantages, a noteworthy feature of the monoblock design is its effective prevention of freezing problems. The system includes automatic anti-freezing protection by constantly monitoring the water temperature within the system. This functionality guarantees the smooth and efficient operation of the system, even in exceptionally frigid weather conditions.
EVI Technology
The full inverter EVI technology incorporated in our heat pump for heating and cooling unit allows for optimal performance even in extremely cold ambient temperatures as low as -25 degrees Celsius, and even -35 degrees Celsius. This advanced technology ensures that the unit provides stable and comfortable house heating as well as a reliable supply of hot water for end users. With the utilization of full inverter EVI technology, our monoblock inverter heat pump for heating and cooling system guarantees efficient and dependable operation in all weather conditions.
With Intelligent Defrosting
HEEALARX’s series of inverter heat pumps for heating and cooling feature advanced intelligent defrosting technology. This innovative technology allows the unit to make intelligent decisions based on the need for defrosting, resulting in minimized energy consumption and improved customer satisfaction.
Best quality heat pump components
In order to ensure the dependable performance of our units, HEEALARX INDUSTRY LIMITED employs premium heat pumpfor heating cooling components, which encompass the ALFA LAVAL Plate heat exchanger, WILO Inverter water pump (made in the EU), Panasonic R32 full inverter compressor, and Panasonic inverter fan motor. These top-notch components, known for their exceptional performance, are meticulously chosen to guarantee optimal efficiency and longevity for our monoblocl inverter heat pump systems.
Installation
HEELARX monoblock full inverter air water heat pumps for heating cooling can provide heating, cooling and domestic hot water. Floor heating loops is used for space heating while fancoil unit can be used for space heating and cooling.
Domestic hot water is supplied from the domestic hot water tank connected to the heat pump.
Traditional Installation
Installation with Multi Functional Tank
Full Inverter Air Water House Heating Heat Pump Monobloc Type | |||||||||
Model | VS90-DC | VS120-DC | VS150-DC | VS180-DC | VS220-DC | VS250-DC | VS300-DC | VS340-DC | |
Power Supply | / | 220V-240V~50Hz/1Ph | 380V-420~50Hz/3Ph | ||||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | |||||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 | 9.5~24.5 | 9.5~29.2 | 12.5~33.3 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 | 2.26~6.69 | 2.26~8.11 | 2.98~9.22 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | 4.21~3.66 | 4.21~3.6 | 4.20~3.61 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | |||||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 | 9.0~24.3 | 9.0~29.4 | 12.2~33.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 | 1.60~5.49 | 1.60~6.61 | 2.20~7.53 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | 5.60~4.43 | 5.60~4.45 | 5.54~4.41 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | |||||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 | 8.5~20.5 | 9.0~23.0 | 10.0~26.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 | 2.16~6.83 | 2.23~7.59 | 2.47~8.38 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | 3.93~3.00 | 4.02~3.03 | 4.05~3.10 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | |||||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 | 8.0~18.0 | 9.0~21.0 | 9.8~24.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 | 2.88~7.20 | 3.27~8.47 | 3.54~9.64 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | 2.78~2.50 | 2.75~2.48 | 2.77~2.49 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | |||||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 | 7.5~15.0 | 9.0~18.0 | 9.5~21.0 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 | 3.13~6.91 | 3.78~8.37 | 4.03~9.86 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | 2.40~2.17 | 2.38~2.15 | 2.36~2.13 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | |||||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 | 5.5~18.0 | 5.5~21.0 | 7.6~24.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 | 1.52~6.67 | 1.52~7.92 | 2.15~8.99 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | 3.62~2.7 | 3.62~2.65 | 3.53~2.67 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 | 4.82 | 4.80 | 4.80 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 | 3.1 | 3.6 | 4.1 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg | R32/2.7kg | R32/2.7kg | R32/3.2kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 | 49 | 51 | 53 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 | 64 | 66 | 68 |
Cabinet Type | / | Galvanized sheet+ABS | |||||||
Compressor Brand | / | Panasonic | |||||||
Fan Motor Type | / | DC motor | |||||||
Operating Ambient Temperature | ℃ | -35~43 | |||||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
Unit Dimensions(L/W/H) | mm | 896×440×750 | 896×440×750 | 1100×440×950 | 1100×440×950 | 1005×440×1400 | 1100×460×1440 | 1100×460×1440 | 1230×545×1525 |
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 992×450×900 | 1195×450×1100 | 1195×450×1100 | 1100×450×1550 | 1195×470×1590 | 1195×470×1590 | 1330×555×1680 |
The above data is for reference only;specific data is subject to the product nameplate. |
Full Inverter Air Water House Heating Heat Pump Monobloc Type | |||||||||
Model | VS90-DC | VS120-DC | VS150-DC | VS180-DC | VS220-DC | VS250-DC | VS300-DC | VS340-DC | |
Power Supply | / | 220V-240V~50Hz/1Ph | 380V-420~50Hz/3Ph | ||||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | |||||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 | 9.5~24.5 | 9.5~29.2 | 12.5~33.3 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 | 2.26~6.69 | 2.26~8.11 | 2.98~9.22 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | 4.21~3.66 | 4.21~3.6 | 4.20~3.61 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | |||||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 | 9.0~24.3 | 9.0~29.4 | 12.2~33.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 | 1.60~5.49 | 1.60~6.61 | 2.20~7.53 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | 5.60~4.43 | 5.60~4.45 | 5.54~4.41 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | |||||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 | 8.5~20.5 | 9.0~23.0 | 10.0~26.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 | 2.16~6.83 | 2.23~7.59 | 2.47~8.38 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | 3.93~3.00 | 4.02~3.03 | 4.05~3.10 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | |||||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 | 8.0~18.0 | 9.0~21.0 | 9.8~24.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 | 2.88~7.20 | 3.27~8.47 | 3.54~9.64 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | 2.78~2.50 | 2.75~2.48 | 2.77~2.49 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | |||||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 | 7.5~15.0 | 9.0~18.0 | 9.5~21.0 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 | 3.13~6.91 | 3.78~8.37 | 4.03~9.86 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | 2.40~2.17 | 2.38~2.15 | 2.36~2.13 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | |||||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 | 5.5~18.0 | 5.5~21.0 | 7.6~24.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 | 1.52~6.67 | 1.52~7.92 | 2.15~8.99 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | 3.62~2.7 | 3.62~2.65 | 3.53~2.67 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 | 4.82 | 4.80 | 4.80 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 | 3.1 | 3.6 | 4.1 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg | R32/2.7kg | R32/2.7kg | R32/3.2kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 | 49 | 51 | 53 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 | 64 | 66 | 68 |
Cabinet Type | / | Galvanized sheet+ABS | |||||||
Compressor Brand | / | Panasonic | |||||||
Fan Motor Type | / | DC motor | |||||||
Operating Ambient Temperature | ℃ | -35~43 | |||||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 |
Unit Dimensions(L/W/H) | mm | 896×440×750 | 896×440×750 | 1100×440×950 | 1100×440×950 | 1005×440×1400 | 1100×460×1440 | 1100×460×1440 | 1230×545×1525 |
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 992×450×900 | 1195×450×1100 | 1195×450×1100 | 1100×450×1550 | 1195×470×1590 | 1195×470×1590 | 1330×555×1680 |
The above data is for reference only;specific data is subject to the product nameplate. |