1.65 Centigrade high water output.
2.WIFI/APP digital touch control.
3.220V and 380v models are available.
4.All models are acquired A+++ ERP approval from TUV( 35 Centigrade A+++ and 55 Centigrade A++).
5.With EVI Technology, can work under -35 centigrade low climate
6.Panasonic twin rotary compressor for outdoor unit.
7.Wide capacity range from 9kw to 22kw for options.
8.Provide solutions for house heating, cooling and also domestic hot water supply.
Availability: | |
---|---|
Quantity: | |
Brief Introduction
HEEALARX Eco Friendly Full Inverter Air Source House Heating Heat Pump for Villas, houses and apartments is specially designed for the European countries such as, Poland, Germany, Netherland, UK, France, Sweden, Finland etc. where there is demand for space heating, cooling and domestic hot water. This full inverter air to water house heating heat pump unit an realize space heating, cooling and domestic sanitary hot water supply via terminal units such as: fan coil unit, floor coil and radiators. It is widely applicable to small and medium sized apartments, large-sized villas, etc.
Features of HEEALARX Inverter Air Water House Heating Heat Pump Split Type
A+++ Energy Label
HEEALARX whole series of eco friendly full inverter air to water house heating heat pump for villas are strictly comply with EN14511 standard, EUROVENT Energy efficiency Class A and SCOP Class A+++ (35C),SCOP CLASS A++(55C) With EN14825 standard.
Super Low Noise Level Technology
with adoption of Panasonic full inverter evi compressor, dc inverter fan motor with changeable fan feed and also well insulation of whole piping and refrigerant system, and the noise level of our heat pump system can reduce to 38 dB.
R32 Green Refrigerant
R32 contributes greatly to the environment protection since green gas of R32 has a low GWP of 675 which is just 32% of R410A. In the HEEALARX DC inverter air to water house heating heat pump system, with lower liquid density, the charge amount of R32 is less than that of R410A, which brings in higher economic efficiency. The heat needed to evaporate R32 is greater than that of R410A so that the required mass flow rate per unit is smaller and the COP is higher.
Best quality heat pump components
As to ensure the stable performance of the units, HEEALARX adopts best quality heat pump components such as: ALFA LAVAL Plate heater exchanger, WILO Inverter water pump made in EU, Panasonic R32 full inverter compressor and Panasonic inverter fan motor etc.
Wifi Digital Touch Control
HEEALARX eco friendly full inverter evi air to water house heating heat pump for villas has a high-end controller with digital colorful touch screen, which is one of the highlights of this trendy heat pump product. It is incredibly convenient for users from different countries that multi language function can be chosen. With wifi /app control, customer can monitor the unit working conditioner via mobile anytime at any place.
EVI DC Inverter Technology
Adopting the most advanced low-temperature Enhanced Vapors Injection compressor technology. HEEALARX Split EVI Full Inverter Air Water House Heating heat pump delivers higher heating capacity at low evaporation temperature thereby better responding to heating requirements than normal inverter air source heat pump, it also results in less supplementary heating to cover the full heating demand on the coldest days. It has been further optimized to enable heat pumps to efficiently produce water temperature up to 65 Centigrade during cold winter time.
Intelligent Defrosting
HEEALARX split full inverter house heating heat pump for villas adopts the intelligent defrosting technology to make optimal decisions on whether it is time to defrost . In this way, the eco friendly inverter house heating heat pump unit is able to minimize energy consumption and improve customer satisfaction.
Anti Freezing Protection
Consisting of an indoor unit that blows air over evaporator coils and an outdoor unit that powers the system, HEEALARX eco friendly full inverter air water house heating heat pump split type for villa model has many advantages to offer homeowners. For example, the split model design can better avoid freezing problems. The system will implement automatic anti-freezing protection by detecting system water temperature.
Installation
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Installation Sketch for domestic hot water and house heating with buffer tank
Brief Introduction
HEEALARX Eco Friendly Full Inverter Air Source House Heating Heat Pump for Villas, houses and apartments is specially designed for the European countries such as, Poland, Germany, Netherland, UK, France, Sweden, Finland etc. where there is demand for space heating, cooling and domestic hot water. This full inverter air to water house heating heat pump unit an realize space heating, cooling and domestic sanitary hot water supply via terminal units such as: fan coil unit, floor coil and radiators. It is widely applicable to small and medium sized apartments, large-sized villas, etc.
Features of HEEALARX Inverter Air Water House Heating Heat Pump Split Type
A+++ Energy Label
HEEALARX whole series of eco friendly full inverter air to water house heating heat pump for villas are strictly comply with EN14511 standard, EUROVENT Energy efficiency Class A and SCOP Class A+++ (35C),SCOP CLASS A++(55C) With EN14825 standard.
Super Low Noise Level Technology
with adoption of Panasonic full inverter evi compressor, dc inverter fan motor with changeable fan feed and also well insulation of whole piping and refrigerant system, and the noise level of our heat pump system can reduce to 38 dB.
R32 Green Refrigerant
R32 contributes greatly to the environment protection since green gas of R32 has a low GWP of 675 which is just 32% of R410A. In the HEEALARX DC inverter air to water house heating heat pump system, with lower liquid density, the charge amount of R32 is less than that of R410A, which brings in higher economic efficiency. The heat needed to evaporate R32 is greater than that of R410A so that the required mass flow rate per unit is smaller and the COP is higher.
Best quality heat pump components
As to ensure the stable performance of the units, HEEALARX adopts best quality heat pump components such as: ALFA LAVAL Plate heater exchanger, WILO Inverter water pump made in EU, Panasonic R32 full inverter compressor and Panasonic inverter fan motor etc.
Wifi Digital Touch Control
HEEALARX eco friendly full inverter evi air to water house heating heat pump for villas has a high-end controller with digital colorful touch screen, which is one of the highlights of this trendy heat pump product. It is incredibly convenient for users from different countries that multi language function can be chosen. With wifi /app control, customer can monitor the unit working conditioner via mobile anytime at any place.
EVI DC Inverter Technology
Adopting the most advanced low-temperature Enhanced Vapors Injection compressor technology. HEEALARX Split EVI Full Inverter Air Water House Heating heat pump delivers higher heating capacity at low evaporation temperature thereby better responding to heating requirements than normal inverter air source heat pump, it also results in less supplementary heating to cover the full heating demand on the coldest days. It has been further optimized to enable heat pumps to efficiently produce water temperature up to 65 Centigrade during cold winter time.
Intelligent Defrosting
HEEALARX split full inverter house heating heat pump for villas adopts the intelligent defrosting technology to make optimal decisions on whether it is time to defrost . In this way, the eco friendly inverter house heating heat pump unit is able to minimize energy consumption and improve customer satisfaction.
Anti Freezing Protection
Consisting of an indoor unit that blows air over evaporator coils and an outdoor unit that powers the system, HEEALARX eco friendly full inverter air water house heating heat pump split type for villa model has many advantages to offer homeowners. For example, the split model design can better avoid freezing problems. The system will implement automatic anti-freezing protection by detecting system water temperature.
Installation
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Installation Sketch for domestic hot water and house heating with buffer tank
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |