Split type full inverter evi air to water house heating heat pump from HEEALARX INDUSTRY LIMITED, adopting word famous manufacturing components such as: Panasonic evi type compressor, ALFA LAVAL Plate heater exchanger, WILO inverter pump, with EVI technology ensure the unit can work under low ambient air temperature of -35 centigrade. Full range of split type full inverter air water house heating heat pump has passed CE approval and also ERP test of A+++.
Availability: | |
---|---|
Quantity: | |
Brief Introduction
Full inverter evi air water house heating heat pump split type consists of separate indoor unit and outdoor unit, developed with the idea in mind for maximum possible energy saving and maximum low noise level, creatively combines eco-friendly R32 refrigerant, full inverter technology and evi technology with modern design, providing powerful heating and cooling performance and modern elegant design in appearance. HEEALARX split type full inverter house heating and cooling heat pump can provide luxurious house heating cooling solutions for both domestic and office buildings.
Features of HEEALARX Inverter Air Water House Heating
Heat Pump Split Type
· High Efficient A+++ Energy Level
Targeting the high end European market, our product of split type full inverter house heating and cooling heat pump can be rated A+++ energy label with full inverter evi technology and the excellent product structure and best quality components we are using. With top energy rating A+++, the unit is currently most energy efficient and cost saving for customers.
Full range of split type full inverter air to water heat pump with evi technology have passed erp tested in TUV lab, which can get A+++ Energy label for 35 centigrade water output.
Description
HEEALARX split type full inverter air water house heating heat hump consists of indoor unit and outdoor unit, The minimalist geometric design element,matched with starry grey ,keep an overall unity and shows the feeling of technology and affinity ,enabling it to be integrated into any household environment.
Anti-freezing protection
Consisting of an indoor unit that blows air over evaporator coils and an outdoor unit that powers the system, split heat pumps have many advantages to offer homeowners. For example, the split model design can better avoid freezing problems. The system will implement automatic anti-freezing protection by detecting system water temperature.
WIFI/APP Control
Through WIFI online monitoring, customers will enjoy our contactless support mode no matter where they are. Our split type HEEALARX full inverter evi air to water home heating heat pump also has more intelligent protection functions.
With Intelligent Defrosting
HEEALARX split inverter heat pump serise adopt the intelligent defrosting technology to make optimal decisions on whether it is time to defrost or not.In this way, the unit is able to minimize energy consumption and improve customer satisfaction.
Full inverter with EVI Technology
with the use of Dc inverter compressor and dc inverter controller,it can automatically increase the operating frequency according to the ambient temperature and greatly improve the heating capacity in low temperature environment.The evi technology with full inverter can ensure the maximum best performance of the heat pump unit during operating at cold ambient temperature as low as -25 centigrade and even -35 centigrade, which can help to offer the end users with stable comfortable house heating and hot water supply.
R32 Low GWP Refrigerant
New gas of R32 environment friendly green gas is in use helps our HEEALARX inverter heat pumps operate more cleanly and effectively, which has less harmful effects on the atmosphere with lower carbon emissions and zero ozone depleting potential.
Super Low Noise Level Technology
with adoption of Panasonic full inverter evi compressor, dc inverter fan motor with changeable fan feed and also well insulation of whole piping and refrigerant system, and the noise level of our heat pump system can reduce to 38 dB.
The large-area fan blade is innovatively used in the outdoor unit.Together with a dc inverter fan motor,the noise of the outdoor unit is reduced to 39db and that of the indoor unit is down to 25db.
Mature full inverter technology:
After 8 years of research, designing and advancement by our international engineer team from Singapore and China, HEEALARX has fully mastered the secret of the mature full inverter technology and also it has applied to our product of split type full inverter house heating and cooling heat pump.
Best quality heat pump components
As to ensure the stable performance of the units, HEEALARX adopts best quality heat pump components such as: ALFA LAVAL Plate heater exchanger, WILO Inverter water pump made in EU, Panasonic R32 full inverter compressor and Panasonic inverter fan motor etc.
Installation
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Installation Sketch for domestic hot water and house heating with buffer tank
Full product range of HEEALARX split type full inverter evi air water house heating cooling heat pump have passed EMC/ LVD test and also got CE certified for Europe.
Brief Introduction
Full inverter evi air water house heating heat pump split type consists of separate indoor unit and outdoor unit, developed with the idea in mind for maximum possible energy saving and maximum low noise level, creatively combines eco-friendly R32 refrigerant, full inverter technology and evi technology with modern design, providing powerful heating and cooling performance and modern elegant design in appearance. HEEALARX split type full inverter house heating and cooling heat pump can provide luxurious house heating cooling solutions for both domestic and office buildings.
Features of HEEALARX Inverter Air Water House Heating
Heat Pump Split Type
· High Efficient A+++ Energy Level
Targeting the high end European market, our product of split type full inverter house heating and cooling heat pump can be rated A+++ energy label with full inverter evi technology and the excellent product structure and best quality components we are using. With top energy rating A+++, the unit is currently most energy efficient and cost saving for customers.
Full range of split type full inverter air to water heat pump with evi technology have passed erp tested in TUV lab, which can get A+++ Energy label for 35 centigrade water output.
Description
HEEALARX split type full inverter air water house heating heat hump consists of indoor unit and outdoor unit, The minimalist geometric design element,matched with starry grey ,keep an overall unity and shows the feeling of technology and affinity ,enabling it to be integrated into any household environment.
Anti-freezing protection
Consisting of an indoor unit that blows air over evaporator coils and an outdoor unit that powers the system, split heat pumps have many advantages to offer homeowners. For example, the split model design can better avoid freezing problems. The system will implement automatic anti-freezing protection by detecting system water temperature.
WIFI/APP Control
Through WIFI online monitoring, customers will enjoy our contactless support mode no matter where they are. Our split type HEEALARX full inverter evi air to water home heating heat pump also has more intelligent protection functions.
With Intelligent Defrosting
HEEALARX split inverter heat pump serise adopt the intelligent defrosting technology to make optimal decisions on whether it is time to defrost or not.In this way, the unit is able to minimize energy consumption and improve customer satisfaction.
Full inverter with EVI Technology
with the use of Dc inverter compressor and dc inverter controller,it can automatically increase the operating frequency according to the ambient temperature and greatly improve the heating capacity in low temperature environment.The evi technology with full inverter can ensure the maximum best performance of the heat pump unit during operating at cold ambient temperature as low as -25 centigrade and even -35 centigrade, which can help to offer the end users with stable comfortable house heating and hot water supply.
R32 Low GWP Refrigerant
New gas of R32 environment friendly green gas is in use helps our HEEALARX inverter heat pumps operate more cleanly and effectively, which has less harmful effects on the atmosphere with lower carbon emissions and zero ozone depleting potential.
Super Low Noise Level Technology
with adoption of Panasonic full inverter evi compressor, dc inverter fan motor with changeable fan feed and also well insulation of whole piping and refrigerant system, and the noise level of our heat pump system can reduce to 38 dB.
The large-area fan blade is innovatively used in the outdoor unit.Together with a dc inverter fan motor,the noise of the outdoor unit is reduced to 39db and that of the indoor unit is down to 25db.
Mature full inverter technology:
After 8 years of research, designing and advancement by our international engineer team from Singapore and China, HEEALARX has fully mastered the secret of the mature full inverter technology and also it has applied to our product of split type full inverter house heating and cooling heat pump.
Best quality heat pump components
As to ensure the stable performance of the units, HEEALARX adopts best quality heat pump components such as: ALFA LAVAL Plate heater exchanger, WILO Inverter water pump made in EU, Panasonic R32 full inverter compressor and Panasonic inverter fan motor etc.
Installation
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Installation Sketch for domestic hot water and house heating with buffer tank
Full product range of HEEALARX split type full inverter evi air water house heating cooling heat pump have passed EMC/ LVD test and also got CE certified for Europe.
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |