1. Both 220v and 380v model are available for full range of split type full inverter air water heat pumps.
2. 35 Centigrade water output can reach A+++, 55 Centigrade water output can reach A++, Certified by TUV.
3. Full range of split inverter air to water house heating heat pump is with CE certified.
4. Wide capacity range from 9kw to 22kw for options.
5. With Full inverter evi technology, ensuring working in low climate of -35 centigrade.
6. ALFA LAVAL Plate heater exchanger, WILO inverter water pump, Honeywell 3 way valve and also Panasonic inverter compressor is in use in full range of split type.
7. Provide solutions for house heating, cooling and also domestic hot water supply.
Availability: | |
---|---|
Quantity: | |
Description
HEEALARX split type Full Inverter Air to Water House Heating Heat Pump for hotels consists of indoor unit and outdoor unit, The minimalist geometric design element ,matched with starry grey ,keep an overall unity and shows the feeling of technology and affinity ,enabling it to be integrated into any household environment.
Features of HEEALARX Inverter Air Water House Heating Heat Pump Split Type
High Efficient A+++ Energy Level
Targeting the high end European market, our product of split type full inverter air source house heating and cooling heat pump water heater for hotel has been certified A+++ energy label by TUV with full inverter evi technology and the excellent product structure and world famous brand components we are using . With top energy rating A+++, the unit is currently most energy efficient and cost saving for customers.Full range of split type full inverter air source heat pump water heat pump for hotel is with evi technology , which successfully passed erp tested in TUV lab, which can get A+++ Energy label for 35 centigrade water output and A++ for 55 centigrade water output.
R32 EVI Technology
with adoption of R32 Dc inverter compressor and dc inverter compatible circuit board ,it can automatically increase the operating frequency according to the different ambient air temperature and greatly improve the heating capacity in low temperature area. The evi technology with full inverter can ensure the maximum best performance of HEEALARX Full Inverter Air to Water House Heating Heat Pump for hotel during operating at low ambient temperature as low as -25 centigrade and even -35 centigrade, which can help to offer the end users with stable and comfortable house heating and domestic hot water supply.
Anti-freezing protection
Consisting of an indoor unit that blows air over evaporator coils and an outdoor unit that powers the system, split heat pumps have many advantages to offer homeowners. For example, the split model design can better avoid freezing problems. The system will implement automatic anti-freezing protection by detecting system water temperature.
With Intelligent Defrostin
HEEALARX split inverter heat pump serise adopt the intelligent defrosting technology to make optimal decisions on whether it is time to defrost or not.In this way, the unit is able to minimize energy consumption and improve customer satisfaction.
R32 Low GWP Gas
Low GWP gas of R32 which is environment friendly, is in use helps our HEEALARX full inverter air to water house heating heat pump for hotel operate more cleanly and effectively, which has less harmful effects on the atmosphere with lower carbon emissions and zero ozone depleting potential.
Super Silent Technology
with adoption of Panasonic full inverter evi compressor, dc inverter fan motor with changeable fan feed and also well insulation of whole piping and refrigerant system, and the noise level of HEEALARX full inverter air source house heating heat pump water heater for hotel can reduce to 40 dB.
The large-area fan blade is innovatively used in the outdoor unit. Together with a dc inverter fan motor, the noise of the outdoor unit is reduced to less than 40 db and that of the indoor unit is down to 25db.
World Famous Brand Heat Pump Components
As to ensure the stable performance of HEEALARX full inverter air water house heating heat pump for hotel , HEEALARX adopts world famous top quality heat pump components such as: ALFA LAVAL Plate heater exchanger, WILO Inverter water pump made in EU, Panasonic R32 full inverter compressor and Panasonic inverter fan motor etc.
WIFI/APP Control
Through WIFI online monitoring, customers will enjoy our contactless support mode no matter where they are. HEEALARX split type full inverter evi air to water house heating heat pump for hotel also has more intelligent protection functions.
Mature Full Inverter Technology
After 8 years of research, designing and advancement by our international engineer team from Singapore and China, HEEALARX has fully mastered the secret of the mature full inverter technology and also it has applied to our product of split type full inverter air to water house heating and cooling heat pump for hotel .
Installation
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Installation Sketch for domestic hot water and house heating with buffer tank
Description
HEEALARX split type Full Inverter Air to Water House Heating Heat Pump for hotels consists of indoor unit and outdoor unit, The minimalist geometric design element ,matched with starry grey ,keep an overall unity and shows the feeling of technology and affinity ,enabling it to be integrated into any household environment.
Features of HEEALARX Inverter Air Water House Heating Heat Pump Split Type
High Efficient A+++ Energy Level
Targeting the high end European market, our product of split type full inverter air source house heating and cooling heat pump water heater for hotel has been certified A+++ energy label by TUV with full inverter evi technology and the excellent product structure and world famous brand components we are using . With top energy rating A+++, the unit is currently most energy efficient and cost saving for customers.Full range of split type full inverter air source heat pump water heat pump for hotel is with evi technology , which successfully passed erp tested in TUV lab, which can get A+++ Energy label for 35 centigrade water output and A++ for 55 centigrade water output.
R32 EVI Technology
with adoption of R32 Dc inverter compressor and dc inverter compatible circuit board ,it can automatically increase the operating frequency according to the different ambient air temperature and greatly improve the heating capacity in low temperature area. The evi technology with full inverter can ensure the maximum best performance of HEEALARX Full Inverter Air to Water House Heating Heat Pump for hotel during operating at low ambient temperature as low as -25 centigrade and even -35 centigrade, which can help to offer the end users with stable and comfortable house heating and domestic hot water supply.
Anti-freezing protection
Consisting of an indoor unit that blows air over evaporator coils and an outdoor unit that powers the system, split heat pumps have many advantages to offer homeowners. For example, the split model design can better avoid freezing problems. The system will implement automatic anti-freezing protection by detecting system water temperature.
With Intelligent Defrostin
HEEALARX split inverter heat pump serise adopt the intelligent defrosting technology to make optimal decisions on whether it is time to defrost or not.In this way, the unit is able to minimize energy consumption and improve customer satisfaction.
R32 Low GWP Gas
Low GWP gas of R32 which is environment friendly, is in use helps our HEEALARX full inverter air to water house heating heat pump for hotel operate more cleanly and effectively, which has less harmful effects on the atmosphere with lower carbon emissions and zero ozone depleting potential.
Super Silent Technology
with adoption of Panasonic full inverter evi compressor, dc inverter fan motor with changeable fan feed and also well insulation of whole piping and refrigerant system, and the noise level of HEEALARX full inverter air source house heating heat pump water heater for hotel can reduce to 40 dB.
The large-area fan blade is innovatively used in the outdoor unit. Together with a dc inverter fan motor, the noise of the outdoor unit is reduced to less than 40 db and that of the indoor unit is down to 25db.
World Famous Brand Heat Pump Components
As to ensure the stable performance of HEEALARX full inverter air water house heating heat pump for hotel , HEEALARX adopts world famous top quality heat pump components such as: ALFA LAVAL Plate heater exchanger, WILO Inverter water pump made in EU, Panasonic R32 full inverter compressor and Panasonic inverter fan motor etc.
WIFI/APP Control
Through WIFI online monitoring, customers will enjoy our contactless support mode no matter where they are. HEEALARX split type full inverter evi air to water house heating heat pump for hotel also has more intelligent protection functions.
Mature Full Inverter Technology
After 8 years of research, designing and advancement by our international engineer team from Singapore and China, HEEALARX has fully mastered the secret of the mature full inverter technology and also it has applied to our product of split type full inverter air to water house heating and cooling heat pump for hotel .
Installation
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Installation Sketch for domestic hot water and house heating with buffer tank
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |