1. A+++ ERP certified by TUV.
2. 220v and 380v are available.
3. With Digital touch app control.
4. Wide Capacity range 9kw/12kw/15kw/18kw/22kw for split range.
5. With EVI Technology, can work under -35 centigrade low climate.
6. Full range of split inverter air to water house heating heat pump is with CE certified.
7. Mature full dc inverter technology are in used for full range of split type
8. Patented noise reduction technology, very quiet operation.
Availability: | |
---|---|
Quantity: | |
Introduction
HEEALARX INDUSTRY LIMITED is delighted to introduce the R32 DC Inverter Air Source High Efficiency Split Inverter Heat Pump for air conditioner, meticulously designed for fan coils, house heating, and domestic hot water applications. This cutting-edge heat pump system comprises a separate indoor unit and outdoor unit, carefully engineered to optimize energy efficiency and reduce noise levels. It seamlessly integrates eco-friendly R32 refrigerant, full inverter technology, and EVI technology, all within a sleek and modern design.
Features of HEEALARX Inverter Air Water House Heating Heat Pump for air conditioner
A+++ Energy Level
Our air source split design split type full inverter heat pump water heater is specifically designed for the high-end European market, catering to cold area and cooling requirements. It offers remarkable performance and is suitable for fan coils, heating, and hot water applications. The advanced full inverter EVI technology, coupled with its superior product structure, enables this heat pump for air conditioner to achieve an impressive A+++ energy label rating. We prioritize the use of the highest quality components to ensure exceptional performance and durability.
If you are looking for top-notch energy efficiency, reliable performance, and superior quality in your house heating and cooling solutions, our air source high efficiency split type full inverter heat pump is an excellent choice.
DC Inverter EVI Technology
Our air source split design split inverter heat pump for cold area unit stands out by incorporating EVI technology and full inverter functionality, allowing it to deliver optimal performance even in extremely low ambient temperatures. This cutting-edge technology enables the unit to operate efficiently and effectively in conditions as low as -25 degrees Celsius, and even as low as -35 degrees Celsius.
By leveraging the benefits of EVI technology and full inverter capabilities, our high efficiency heat pump for air conditioner ensures stable and comfortable house heating, cooling, and hot water supply for end users. Regardless of the external temperature, the unit is designed to maintain a consistent and comfortable indoor environment, providing reliable heating and cooling performance as well as a steady supply of hot water.
R32 Gas
HEEALARX showcases its dedication to energy efficiency and environmental responsibility by incorporating R32 gas in our Air to Water Split Inverter Heat Pump designed for cold areas. We strive to offer our customers a state-of-the-art heating and cooling solution that not only saves energy but also contributes to the reduction of carbon emissions, fostering a cleaner and more sustainable future.
Top Brand Inverter Heat Pump Parts
HEEALARX places utmost importance on the stable performance of our split design split inverter heat pump units, which is why we only use top-quality components. Our units are equipped with renowned components such as the ALFA LAVAL Plate heat exchanger, WILO Inverter water pump (manufactured in the EU), Panasonic R32 full inverter compressor, and Panasonic inverter fan motor. These components are meticulously chosen for their exceptional quality and reliability, guaranteeing optimal performance and longevity of our split full inverter air to water eco-friendly house heating heat pump for clubs.
Digital Wifi Touch Cont
The HEEALARX Air Source high efficiency Split Inverter Heat Pump for air conditioner, designed for modern radiators, fan coils, house heating, and hot water applications, features a full-color control panel with a square gradient effect. This design element not only enhances the overall interface but also adds a visually stunning impact to the unit. Additionally, the control panel can be detached and used separately, offering greater flexibility in placement.
With digital touch controls, the high efficiency heat pump provides easy operation and adjustment. Furthermore, the inclusion of WIFI connectivity allows users to control their heat pump from anywhere using a dedicated smartphone app. This convenient functionality enables users to monitor and adjust their heat pump settings remotely, ensuring optimal comfort and energy efficiency.
HEEALARX remains committed to user-friendly designs and advanced technology, providing customers with a seamless and convenient experience when operating their air source split inverter heat pump system.
Mature full inverter technology
HEEALARX is proud to announce the successful culmination of 8 years of research, design, and development by our international engineering team based in Singapore and China. Through their dedicated efforts, we have achieved mastery in the mature full inverter technology, which has been successfully integrated into our split-type full inverter heat pump for air conditioning, providing efficient house heating and cooling solutions.
Quiet Running
HEEALARX’s Split design split Full Inverter Air to Water Eco Friendly House Heating Heat Pump for air conditioning in clubs is equipped with a unique soundproof internal structure that effectively reduces sound pressure levels. At a distance of 1 meter, and with the minimum flow rate, the sound pressure is maintained as low as 40dB(A). This ensures a quiet and comfortable environment for users, minimizing noise disturbances.
We prioritize the use of top-brand inverter heat pump for air conditioner parts to ensure the stable performance of our split design split inverter heat pump units. These include the ALFA LAVAL Plate heat exchanger, WILO Inverter water pump (manufactured in the EU), Panasonic R32 full inverter compressor, and Panasonic inverter fan motor. These renowned components are carefully selected for their superior quality and reliability, guaranteeing optimal performance and longevity of our split full inverter air to water eco-friendly house heating heat pump for clubs.
Stable Running at -35℃ Low Ambient Temperature
Traditional split design split inverter heat pumps often face limitations in performance when operating under low ambient temperatures. Firstly, their heating ability tends to weaken as the ambient temperature decreases. Secondly, the stability and reliability of the machine can be compromised in low temperature environments. Lastly, the operating range and safety range can impact the overall performance of the heat pump for air conditioning.
However, HEEALARX’s split type full inverter air to water for air conditioner eco-friendly house heating heat pump for clubs, equipped with the unique Inverter EVI technology, overcomes these limitations. It is capable of operating efficiently even at extremely low temperatures as low as -35°C. This innovative technology ensures that the heat pump maintains a high coefficient of performance (COP) and guarantees reliable stability in challenging cold environments.
Installation
HEEALARX Full split design split inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Installation Sketch for domestic hot water and house heating with buffer tank
Introduction
HEEALARX INDUSTRY LIMITED is delighted to introduce the R32 DC Inverter Air Source High Efficiency Split Inverter Heat Pump for air conditioner, meticulously designed for fan coils, house heating, and domestic hot water applications. This cutting-edge heat pump system comprises a separate indoor unit and outdoor unit, carefully engineered to optimize energy efficiency and reduce noise levels. It seamlessly integrates eco-friendly R32 refrigerant, full inverter technology, and EVI technology, all within a sleek and modern design.
Features of HEEALARX Inverter Air Water House Heating Heat Pump for air conditioner
A+++ Energy Level
Our air source split design split type full inverter heat pump water heater is specifically designed for the high-end European market, catering to cold area and cooling requirements. It offers remarkable performance and is suitable for fan coils, heating, and hot water applications. The advanced full inverter EVI technology, coupled with its superior product structure, enables this heat pump for air conditioner to achieve an impressive A+++ energy label rating. We prioritize the use of the highest quality components to ensure exceptional performance and durability.
If you are looking for top-notch energy efficiency, reliable performance, and superior quality in your house heating and cooling solutions, our air source high efficiency split type full inverter heat pump is an excellent choice.
DC Inverter EVI Technology
Our air source split design split inverter heat pump for cold area unit stands out by incorporating EVI technology and full inverter functionality, allowing it to deliver optimal performance even in extremely low ambient temperatures. This cutting-edge technology enables the unit to operate efficiently and effectively in conditions as low as -25 degrees Celsius, and even as low as -35 degrees Celsius.
By leveraging the benefits of EVI technology and full inverter capabilities, our high efficiency heat pump for air conditioner ensures stable and comfortable house heating, cooling, and hot water supply for end users. Regardless of the external temperature, the unit is designed to maintain a consistent and comfortable indoor environment, providing reliable heating and cooling performance as well as a steady supply of hot water.
R32 Gas
HEEALARX showcases its dedication to energy efficiency and environmental responsibility by incorporating R32 gas in our Air to Water Split Inverter Heat Pump designed for cold areas. We strive to offer our customers a state-of-the-art heating and cooling solution that not only saves energy but also contributes to the reduction of carbon emissions, fostering a cleaner and more sustainable future.
Top Brand Inverter Heat Pump Parts
HEEALARX places utmost importance on the stable performance of our split design split inverter heat pump units, which is why we only use top-quality components. Our units are equipped with renowned components such as the ALFA LAVAL Plate heat exchanger, WILO Inverter water pump (manufactured in the EU), Panasonic R32 full inverter compressor, and Panasonic inverter fan motor. These components are meticulously chosen for their exceptional quality and reliability, guaranteeing optimal performance and longevity of our split full inverter air to water eco-friendly house heating heat pump for clubs.
Digital Wifi Touch Cont
The HEEALARX Air Source high efficiency Split Inverter Heat Pump for air conditioner, designed for modern radiators, fan coils, house heating, and hot water applications, features a full-color control panel with a square gradient effect. This design element not only enhances the overall interface but also adds a visually stunning impact to the unit. Additionally, the control panel can be detached and used separately, offering greater flexibility in placement.
With digital touch controls, the high efficiency heat pump provides easy operation and adjustment. Furthermore, the inclusion of WIFI connectivity allows users to control their heat pump from anywhere using a dedicated smartphone app. This convenient functionality enables users to monitor and adjust their heat pump settings remotely, ensuring optimal comfort and energy efficiency.
HEEALARX remains committed to user-friendly designs and advanced technology, providing customers with a seamless and convenient experience when operating their air source split inverter heat pump system.
Mature full inverter technology
HEEALARX is proud to announce the successful culmination of 8 years of research, design, and development by our international engineering team based in Singapore and China. Through their dedicated efforts, we have achieved mastery in the mature full inverter technology, which has been successfully integrated into our split-type full inverter heat pump for air conditioning, providing efficient house heating and cooling solutions.
Quiet Running
HEEALARX’s Split design split Full Inverter Air to Water Eco Friendly House Heating Heat Pump for air conditioning in clubs is equipped with a unique soundproof internal structure that effectively reduces sound pressure levels. At a distance of 1 meter, and with the minimum flow rate, the sound pressure is maintained as low as 40dB(A). This ensures a quiet and comfortable environment for users, minimizing noise disturbances.
We prioritize the use of top-brand inverter heat pump for air conditioner parts to ensure the stable performance of our split design split inverter heat pump units. These include the ALFA LAVAL Plate heat exchanger, WILO Inverter water pump (manufactured in the EU), Panasonic R32 full inverter compressor, and Panasonic inverter fan motor. These renowned components are carefully selected for their superior quality and reliability, guaranteeing optimal performance and longevity of our split full inverter air to water eco-friendly house heating heat pump for clubs.
Stable Running at -35℃ Low Ambient Temperature
Traditional split design split inverter heat pumps often face limitations in performance when operating under low ambient temperatures. Firstly, their heating ability tends to weaken as the ambient temperature decreases. Secondly, the stability and reliability of the machine can be compromised in low temperature environments. Lastly, the operating range and safety range can impact the overall performance of the heat pump for air conditioning.
However, HEEALARX’s split type full inverter air to water for air conditioner eco-friendly house heating heat pump for clubs, equipped with the unique Inverter EVI technology, overcomes these limitations. It is capable of operating efficiently even at extremely low temperatures as low as -35°C. This innovative technology ensures that the heat pump maintains a high coefficient of performance (COP) and guarantees reliable stability in challenging cold environments.
Installation
HEEALARX Full split design split inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Installation Sketch for domestic hot water and house heating with buffer tank
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |