1. A+++ ERP certified by TUV.
2. 220v and 380v are available.
3. Low GWP gas of R32 or R290
4. Panasonic twin rotary compressor for outdoor unit.
5. Both 220v and 380v model are available for full range of split type full inverter air water heat pumps.
6. With Full inverter evi technology, ensuring working in low climate of -35 centigrade.
7. Provide solutions for house heating, cooling and also domestic hot water supply.
8. Full range of split inverter air to water house heating heat pump is with CE certified.
Availability: | |
---|---|
Quantity: | |
Brief Introduction
Split type full inverter house heating and cooling heat pump consists of separate indoor unit and outdoor unit, developed with the idea in mind for maximum possible energy saving and maximum low noise level, creatively combines eco-friendly R32 refrigerant, full inverter technology and evi technology with modern design, providing powerful heating and cooling performance and modern elegant design in appearance. HEEALARX split type full inverter house heating and cooling heat pump can provide luxurious house heating cooling solutions for both domestic and office buildings.
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Advantage of HEEALARX Inverter Air Water House Heating Heat Pump Split Type
A+++ Energy Label
Targeting the high end European market, our product of split type full inverter house heating and cooling heat pump can be rated A+++ energy label with full inverter evi technology and the excellent product structure and best quality components we are using. With top energy rating A+++, the unit is currently most energy efficient and cost saving for customers.
Mature full inverter technology:
After 8 years of research, designing and advancement by our international engineer team from Singapore and China, HEEALARX has fully mastered the secret of the mature full inverter technology and also it has applied to our product of split type full inverter house heating and cooling heat pump.
EVI Technology
The evi technology with full inverter can ensure the maximum best performance of the heat pump unit during operating at cold ambient temperature as low as -25 centigrade and even -35 centigrade, which can help to offer the end users with stable comfortable house heating and hot water supply.
Super Low Noise Level Technology
with adoption of Panasonic full inverter evi compressor, dc inverter fan motor with changeable fan feed and also well insulation of whole piping and refrigerant system, and the noise level of our heat pump system can reduce to 38 dB.
Best quality heat pump components
As to ensure the stable performance of the units, HEEALARX adopts best quality heat pump components such as: ALFA LAVAL Plate heater exchanger, WILO Inverter water pump made in EU, Panasonic R32 full inverter compressor and Panasonic inverter fan motor etc.
WIFI/APP Control
Digital touch control with WIFI, can control your heat pump anywhere with app on your smartphone.
R32 Gas
New gas of R32 environment friendly green gas is in use, 10%-20% more efficient than R410A and also low carbon consumption.
Smart Digital Touch Control
HEEALARX full inverter evi air to water split type house heating heat heat pump has a high-end controller with digital colorful touch screen, which is one of the highlights of this trendy heat pump product. It is incredibly convenient for users from different countries that multi language function can be chosen.
Installation
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for domestic hot water and house heating with buffer tank
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Brief Introduction
Split type full inverter house heating and cooling heat pump consists of separate indoor unit and outdoor unit, developed with the idea in mind for maximum possible energy saving and maximum low noise level, creatively combines eco-friendly R32 refrigerant, full inverter technology and evi technology with modern design, providing powerful heating and cooling performance and modern elegant design in appearance. HEEALARX split type full inverter house heating and cooling heat pump can provide luxurious house heating cooling solutions for both domestic and office buildings.
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Advantage of HEEALARX Inverter Air Water House Heating Heat Pump Split Type
A+++ Energy Label
Targeting the high end European market, our product of split type full inverter house heating and cooling heat pump can be rated A+++ energy label with full inverter evi technology and the excellent product structure and best quality components we are using. With top energy rating A+++, the unit is currently most energy efficient and cost saving for customers.
Mature full inverter technology:
After 8 years of research, designing and advancement by our international engineer team from Singapore and China, HEEALARX has fully mastered the secret of the mature full inverter technology and also it has applied to our product of split type full inverter house heating and cooling heat pump.
EVI Technology
The evi technology with full inverter can ensure the maximum best performance of the heat pump unit during operating at cold ambient temperature as low as -25 centigrade and even -35 centigrade, which can help to offer the end users with stable comfortable house heating and hot water supply.
Super Low Noise Level Technology
with adoption of Panasonic full inverter evi compressor, dc inverter fan motor with changeable fan feed and also well insulation of whole piping and refrigerant system, and the noise level of our heat pump system can reduce to 38 dB.
Best quality heat pump components
As to ensure the stable performance of the units, HEEALARX adopts best quality heat pump components such as: ALFA LAVAL Plate heater exchanger, WILO Inverter water pump made in EU, Panasonic R32 full inverter compressor and Panasonic inverter fan motor etc.
WIFI/APP Control
Digital touch control with WIFI, can control your heat pump anywhere with app on your smartphone.
R32 Gas
New gas of R32 environment friendly green gas is in use, 10%-20% more efficient than R410A and also low carbon consumption.
Smart Digital Touch Control
HEEALARX full inverter evi air to water split type house heating heat heat pump has a high-end controller with digital colorful touch screen, which is one of the highlights of this trendy heat pump product. It is incredibly convenient for users from different countries that multi language function can be chosen.
Installation
HEEALARX Full inverter evi air water house heating heat pump is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for domestic hot water and house heating with buffer tank
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 220V-240V~50Hz/1Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 220V-240V~50Hz/1Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |