1.Low Noise level, quiet operation.
2.EVI Technology cold climate working insurance.
3.CE approved for full range
4.Wide capacity range from 9kw to 22kw.
5.All split type are with EVI technology, ensuring heat pump can work well under low ambient temperature of -35 centigrade.
6.Indoor unit with ALFA LAVAL Plate heater exchanger, WILO inverter water pump , Honeywell 3 way valve and auxiliary electrical heater.
7.Full range of split inverter air to water house heating heat pump is with CE certified.
8.Provide solutions for house heating, cooling and also domestic hot water supply.
Availability: | |
---|---|
Quantity: | |
Introduction
The HEEALARX air source split type full inverter heat pump for hospitals and house heating is specifically designed to meet the heating and cooling needs of fan coils, as well as provide domestic hot water. This heat pump with wifi app control system features a split-type configuration, with separate indoor and outdoor units, ensuring efficient operation and minimal noise levels. Our engineering team has focused on maximizing energy efficiency by incorporating eco-friendly R32 refrigerant, full inverter technology, and evi technology. The result is a modern and elegant design that not only delivers powerful heating and cooling performance but also enhances the overall aesthetic appeal of domestic and office buildings.
Features of HEEALARX Inverter Air Water House Heating Heat Pump with wifi app control Split Type
High Efficient A+++ Energy Level Verified by TUV
Our heat pump for hospitals, designed for fan coils, heating, and hot water applications, is a split-type full inverter air source heat pump with wifi app control that specifically caters to the high-end European market. It boasts an impressive A+++ energy label rating, which has been certified by TUV, a well-known certification body.
One of the key features of our air source splti type heat pump is its adjustable compressor running capacity. This allows for flexible and efficient operation, as the unit can vary its capacity from 30% to 150%. This ensures precise control and optimal performance based on the heating and cooling demands.
Furthermore, our heat pump with wifi app control unit is built with excellent product structure and utilizes top-quality components. The incorporation of full inverter EVI technology further enhances the energy efficiency of the unit. With these features, our split type heat pump provides reliable and efficient heating and cooling solutions for hospitals, while also reducing energy consumption.
In summary, our air source split type full inverter heat pump for hospitals is a top choice for the high-end European market, offering exceptional energy efficiency, precise control, and reliable performance.
Mature full inverter technology
Our international team of engineers from Singapore and China has been devoted to 8 years of research, design, and technological advancements. As a result, we have successfully integrated mature full inverter technology into our air source split type split inverter heat pump with wifi app control. This state-of-the-art technology is specifically tailored for fan coils, heating, and domestic hot water applications.
Super Low Noise Level Technology
The HEEALARX air source split type inverter heat pump for hospitals features an outdoor unit equipped with an innovative large-area fan blade and a DC inverter fan motor, which effectively reduces noise levels. The outdoor unit noise is kept below 40dB, while the indoor unit operates with a noise level as low as 25dB. This exceptional noise reduction is achieved through the incorporation of a Panasonic full inverter EVI type compressor, a DC inverter fan motor with adjustable fan speed, and efficient insulation of the entire piping and refrigerant system. We are proud to offer a heat pump system that not only delivers exceptional performance but also prioritizes quiet operation. Thank you for choosing our product.
EVI Technology
Our air source split inverter heat pump for hospitals unit is equipped with both EVI technology and full inverter functionality, allowing it to deliver exceptional performance even in extremely low ambient temperatures. With the ability to operate in temperatures as low as -25 degrees Celsius and even -35 degrees Celsius, this unit ensures stable and comfortable house heating, cooling, and hot water supply for end users. By effectively functioning in such harsh cold environments, our split type heat pump for hospitals unit guarantees reliable performance and enhances overall comfort and satisfaction.
Smart Digital Touch Control
The HEEALAX Air Source Split Inverter Heat Pump for hospitals, designed for fan coils, house heating, and hot water applications, is equipped with a modern and visually appealing full-color control panel. The control panel incorporates a square gradient effect, creating a visually striking interface. Additionally, the control panel can be detached and used separately, providing users with greater flexibility in terms of placement.
The heat pump with wifi app control system also features digital touch control and WIFI connectivity. This allows users to conveniently control and manage their heat pump from anywhere using a dedicated smartphone app. The inclusion of these advanced features enhances the overall user experience by providing easy and convenient management of the split type heat pump system.
R32 Gas
The HEEALARX Air to Water Split Inverter Heat Pump with wifi app control units for hospitals make use of the eco-friendly R32 refrigerant, which is a new generation green gas. When compared to R410A, R32 offers a 10%-20% increase in efficiency and lower carbon consumption. This deliberate choice not only enhances energy efficiency but also reduces the overall environmental impact, showcasing our dedication to sustainability.
World Famous Brand Heat Pump Components
HEEALARX places great emphasis on the reliable performance of our air source split inverter heat pump with wifi app control units. To achieve this, we incorporate renowned and globally recognized brand components. These components include the ALFA LAVAL Plate heat exchanger, the EU-manufactured WILO Inverter water pump, the Panasonic R32 full inverter compressor, and the Panasonic inverter fan motor. Our meticulous selection of these components is based on their exceptional quality and proven reliability. By utilizing these components, we guarantee the optimal performance and long-lasting durability of our split type heat pump units.
Installation
HEEALARX Full inverter evi air water house heating heat pump with wifi app control is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for domestic hot water and house heating with buffer tank
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Introduction
The HEEALARX air source split type full inverter heat pump for hospitals and house heating is specifically designed to meet the heating and cooling needs of fan coils, as well as provide domestic hot water. This heat pump with wifi app control system features a split-type configuration, with separate indoor and outdoor units, ensuring efficient operation and minimal noise levels. Our engineering team has focused on maximizing energy efficiency by incorporating eco-friendly R32 refrigerant, full inverter technology, and evi technology. The result is a modern and elegant design that not only delivers powerful heating and cooling performance but also enhances the overall aesthetic appeal of domestic and office buildings.
Features of HEEALARX Inverter Air Water House Heating Heat Pump with wifi app control Split Type
High Efficient A+++ Energy Level Verified by TUV
Our heat pump for hospitals, designed for fan coils, heating, and hot water applications, is a split-type full inverter air source heat pump with wifi app control that specifically caters to the high-end European market. It boasts an impressive A+++ energy label rating, which has been certified by TUV, a well-known certification body.
One of the key features of our air source splti type heat pump is its adjustable compressor running capacity. This allows for flexible and efficient operation, as the unit can vary its capacity from 30% to 150%. This ensures precise control and optimal performance based on the heating and cooling demands.
Furthermore, our heat pump with wifi app control unit is built with excellent product structure and utilizes top-quality components. The incorporation of full inverter EVI technology further enhances the energy efficiency of the unit. With these features, our split type heat pump provides reliable and efficient heating and cooling solutions for hospitals, while also reducing energy consumption.
In summary, our air source split type full inverter heat pump for hospitals is a top choice for the high-end European market, offering exceptional energy efficiency, precise control, and reliable performance.
Mature full inverter technology
Our international team of engineers from Singapore and China has been devoted to 8 years of research, design, and technological advancements. As a result, we have successfully integrated mature full inverter technology into our air source split type split inverter heat pump with wifi app control. This state-of-the-art technology is specifically tailored for fan coils, heating, and domestic hot water applications.
Super Low Noise Level Technology
The HEEALARX air source split type inverter heat pump for hospitals features an outdoor unit equipped with an innovative large-area fan blade and a DC inverter fan motor, which effectively reduces noise levels. The outdoor unit noise is kept below 40dB, while the indoor unit operates with a noise level as low as 25dB. This exceptional noise reduction is achieved through the incorporation of a Panasonic full inverter EVI type compressor, a DC inverter fan motor with adjustable fan speed, and efficient insulation of the entire piping and refrigerant system. We are proud to offer a heat pump system that not only delivers exceptional performance but also prioritizes quiet operation. Thank you for choosing our product.
EVI Technology
Our air source split inverter heat pump for hospitals unit is equipped with both EVI technology and full inverter functionality, allowing it to deliver exceptional performance even in extremely low ambient temperatures. With the ability to operate in temperatures as low as -25 degrees Celsius and even -35 degrees Celsius, this unit ensures stable and comfortable house heating, cooling, and hot water supply for end users. By effectively functioning in such harsh cold environments, our split type heat pump for hospitals unit guarantees reliable performance and enhances overall comfort and satisfaction.
Smart Digital Touch Control
The HEEALAX Air Source Split Inverter Heat Pump for hospitals, designed for fan coils, house heating, and hot water applications, is equipped with a modern and visually appealing full-color control panel. The control panel incorporates a square gradient effect, creating a visually striking interface. Additionally, the control panel can be detached and used separately, providing users with greater flexibility in terms of placement.
The heat pump with wifi app control system also features digital touch control and WIFI connectivity. This allows users to conveniently control and manage their heat pump from anywhere using a dedicated smartphone app. The inclusion of these advanced features enhances the overall user experience by providing easy and convenient management of the split type heat pump system.
R32 Gas
The HEEALARX Air to Water Split Inverter Heat Pump with wifi app control units for hospitals make use of the eco-friendly R32 refrigerant, which is a new generation green gas. When compared to R410A, R32 offers a 10%-20% increase in efficiency and lower carbon consumption. This deliberate choice not only enhances energy efficiency but also reduces the overall environmental impact, showcasing our dedication to sustainability.
World Famous Brand Heat Pump Components
HEEALARX places great emphasis on the reliable performance of our air source split inverter heat pump with wifi app control units. To achieve this, we incorporate renowned and globally recognized brand components. These components include the ALFA LAVAL Plate heat exchanger, the EU-manufactured WILO Inverter water pump, the Panasonic R32 full inverter compressor, and the Panasonic inverter fan motor. Our meticulous selection of these components is based on their exceptional quality and proven reliability. By utilizing these components, we guarantee the optimal performance and long-lasting durability of our split type heat pump units.
Installation
HEEALARX Full inverter evi air water house heating heat pump with wifi app control is designed for house heating, domestic hot water supply and cooling in low ambient air temperature of -25 centigrade to -35 centigrade.
Installation Sketch for domestic hot water and house heating with buffer tank
Installation Sketch for house heating, domestic hot water and cooling with buffer tank
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |
Full Inverter Air Water House Heating Heat Pump Split Type | ||||||
Complete model | VS90-DCS | VS120-DCS | VS150-DCS | VS180-DCS | VS220-DCS | |
External model number | VS90-DCS-FW | VS120-DCS-FW | VS150-DCS-FW | VS180-DCS-FW | VS220-DCS-FW | |
Power Supply | / | 380V~50Hz/3Ph | ||||
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):40/45℃ | ||||||
Heating Capacity Range | kW | 3.8~9.0 | 3.8~11.0 | 5.5~15.0 | 5.5~17.5 | 7.3~21.5 |
Heating Power Input Range | kW | 0.89~2.48 | 0.89~3.06 | 1.31~4.11 | 1.31~4.85 | 1.73~5.91 |
COP | 4.25~3.63 | 4.25~3.6 | 4.20~3.65 | 4.20~3.61 | 4.22~3.64 | |
Heating Condition-Ambient Temp.(DB/WB):7/6℃,Water Temp.(In/Out):30/35℃ | ||||||
Heating Capacity Range | kW | 3.7~8.5 | 3.7~10.7 | 5.2~14.6 | 5.2~17.4 | 7.0~21.2 |
Heating Power Input Range | kW | 0.67~1.91 | 0.67~2.40 | 0.94~3.28 | 0.94~3.95 | 1.27~4.75 |
COP | 5.55~4.45 | 5.55~4.46 | 5.56~4.45 | 5.56~4.41 | 5.52~4.46 | |
Heating Condition-Ambient Temp.(DB/WB):-5/-6℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.5~7.0 | 4.0~8.5 | 4.5~13.0 | 5.0~15.0 | 5.5~17.0 |
Heating Power Input Range | kW | 0.91~2.33 | 1.06~2.85 | 1.17~4.30 | 1.30~5.98 | 1.40~5.45 |
COP | 3.80~3.00 | 3.78~2.98 | 3.85~3.02 | 3.83~3.01 | 3.95~3.12 | |
Heating Condition-Ambient Temp.(DB/WB):-12/-13.5℃,Water Temp.(In/Out):36/41℃ | ||||||
Heating Capacity Range | kW | 3.0~6.0 | 4.0~7.5 | 4.0~11.0 | 4.5~13.0 | 5.0~15.0 |
Heating Power Input Range | kW | 1.11~2.45 | 1.50~3.06 | 1.45~4.40 | 1.65~5.30 | 1.79~5.88 |
COP | 2.70~2.45 | 2.68~2.45 | 2.75~2.50 | 2.72~2.48 | 2.80~2.55 | |
Heating Condition-Ambient Temp.(DB/WB):-20/~℃,Water Temp.(In/Out):~/41℃ | ||||||
Heating Capacity Range | kW | 2.5~5.0 | 3.0~6.0 | 3.8~9.5 | 4.3~11.0 | 4.7~12.5 |
Heating Power Input Range | kW | 1.04~2.33 | 1.26~2.79 | 1.59~4.44 | 1.80~5.19 | 1.92~5.68 |
COP | 2.40~2.15 | 2.38~2.15 | 2.39~2.14 | 2.38~2.12 | 2.45~2.20 | |
Cooling Condition-Ambient Temp.(DB/WB):35/24℃,Water Temp.(In/Out):12/7℃ | ||||||
Cooling Capacity Range | kW | 2.3~6.5 | 2.3~8.0 | 3.2~11.0 | 3.2~13.0 | 4.5~15.0 |
Cooling Power Input Range | kW | 0.65~2.45 | 0.65~3.04 | 0.90~4.10 | 0.90~4.96 | 1.25~5.68 |
EER | 3.53~2.65 | 3.53~2.63 | 3.55~2.68 | 3.55~2.62 | 3.6~2.64 | |
ErP Level(35℃) | / | A+++ | A+++ | A+++ | A+++ | A+++ |
SCOP(35℃) | / | 4.81 | 4.82 | 4.82 | 4.80 | 4.81 |
Water Flow | m³ | 1.1 | 1.4 | 1.9 | 2.2 | 2.6 |
Refrigerant/Proper Input | kg | R32/1.2kg | R32/1.2kg | R32/1.8kg | R32/1.8kg | R32/2.3kg |
Sound Pressure At Rated Flow (1m) | dB(A) | 42 | 43 | 45 | 46 | 47 |
Sound Power LevelEN12102 (35℃) | dB(A) | 57 | 59 | 60 | 61 | 62 |
Cabinet Type | / | Galvanized sheet+ABS | ||||
Compressor Brand | / | Panasonic | ||||
Fan Motor Type | / | DC motor | ||||
Operating Ambient Temperature | ℃ | -35~43 | ||||
Water Connection | inch | 1 | 1 | 1.2 | 1.2 | 1.2 |
Refrigerant circuit | Liquid Dia(OD):φ9.52 / Gas Dia(OD):φ15.88 | |||||
Net weight | kg | 65 | 70 | 90 | 105 | 115 |
Unit Dimensions(L/W/H) | mm | 945×440×750 | 1145×440×950 | 1055×440×1400 | ||
Shipping Dimensions(L/W/H) | mm | 990×450×900 | 1195×450×1100 | 1100×450×1550 | ||
The above data is for reference only;specific data is subject to the product nameplate. |